  • Model: GASTAT – 1800 series

    Manufactured by: Techno Medica – Japan

    • Short analysis time: 50 seconds (Model GASTAT-1820)
    • Small sample volume: 80 μL for capillary and 120 μL for syringe (Model GASTAT-1820)
    • Acid-base graph available
    • Throw-in-type printer realizes easy paper roll replacement
    • Save mode reduces reagent consumption for users having less samples in the midnight
    • Automatic Quality Control conveniently guarantees accuracy of test results
    • Built-in PC functionality for intercommunicate without using external PC
    • Built-in battery enables 30 minutes stable operation or 5 samples analysis under power failure

    Ultrafast Sample Aspiration

    4 seconds’ sample aspiration time realizes short. Turn-Around-Time. (Model GASTAT-1820)

    Touch-Sensitive Panel

    The 12 inch color touch panel conveniently displays easy-to follow guidance for every operation.

    Built-in Barcode Reader

    Built-in barcode reader reduces errors and save time for users.

    Injection Detect Function

    The system starts automatic cleaning when sample is injected.

    Zero-maintenance Electrodes

    The stable high-precision performance electrodes enable absolutely maintenance free.

    Minimal Reagents Replacement Required

    Only two kinds of reagents required (CAL Cartridge and FLUSH SOLUTION).

    • Specimen: Whole blood, Serum, Plazma, Dialysate
    • Test available (measured):

    pH: 6.0 – 8.0

    pCO2: 10.0-200.0Torr

    pO2: 10.0-760Torr

    cHb: 2.0 – 23.0 g/dL

    • Test available (calculated): cHCO₃⁻act, cHCO₃⁻std, cBE(ecf), cBE(B), cBB,ctCO₂(P), ctCO₂(B), sO₂(est), BO₂, p50, p50(T), p50(st), pO₂/FiO₂, pO2₂(A,T), pO₂(A), pO₂(A-a), pO₂(A-a,T), pO₂(a/A), pO₂(a/A,T), RI, RI(T), ctO₂(a), ctO₂(B), ctO₂(v), ctO₂(a-v), ctO₂([a-v]/a), Hct
    • Entered parameter: Patient ID, Patient temperature, Patient Hb, Barometric pressure, FiO2, Height, Weight, Sex, Age.
    • Sample volume: 60µl in capillary , 120 µl in syringe
    • Analysis time GASTAT-1810/1820(aqc) (from press measurement button to result appears on the display): 50 giây
    • Sample aspiration time: 4 seconds
    • Display: 12 inch full color display/touch panel
    • Calibration: Automatic, programmable 1 and 2 point calibration
    • Data storage: 10,000 samples
    • Printer: Line thermal
    • Interface: TCP/IP
    • Barcode reader: Built-in (12 kinds of barcode are available)
    • Power: 85 – 264V 50/60Hz 150W, Built-in Battery
    • Dimensions: 330(W) – 420(D) – 570(H) mm
    • Weight: 5 kg